Geeklog Site http://lethalclan.com/hvac Another Nifty Geeklog Site admin@lethalclan.com admin@lethalclan.com Copyright 2007 HVAC TECH GROUP GeekLog Thu, 03 May 2007 02:22:37 -0400 en-gb Welcome to the HVAC Technician Page http://lethalclan.com/hvac/article.php?story=welcome http://lethalclan.com/hvac/article.php?story=welcome Tue, 01 May 2007 13:15:27 -0400 General News This is a place for HVAC technicians to share information and discuss trade related topics.<br>Please note that all code references are from the CAN/CSA-B149.1-05, Natural gas and propane installation code.<br><br>Please sign-up in the <a target="_blank" href="/hvacforum/"><font size="1">Forum</font></a>, to post or comment. Enjoy your stay.<br><br> CAN/CSA-B149.1-05 - Supplement No. 1 http://lethalclan.com/hvac/article.php?story=20070428191503228 http://lethalclan.com/hvac/article.php?story=20070428191503228 Sat, 28 Apr 2007 19:15:03 -0400 B149.1-05 News TSSA adopts the new CAN/CSA B149.1S1-07 supplement August 1st, 2007;<br><br>Download the <a target="_blank" href="/hvac/files/B149_1S1_EN.pdf"><b><font size="1">B149.1S1-07 Supplement</font></b></a><br>Download the <a target="_blank" href="/hvac/files/B149_1U1_EN.pdf"><b><font size="1">B149.1-05 Update No. 1</font></b></a><br>&nbsp;&nbsp;<i>*This update corrects Clause 8.2.3, which mistakenly refers to Clause 8.2.5. The Update No. 1 revises Clause 8.2.3, to refer to Clause 8.2.6.</i> TSSA's Code Adoption Document FS-098-07 http://lethalclan.com/hvac/article.php?story=20070428191230140 http://lethalclan.com/hvac/article.php?story=20070428191230140 Sat, 28 Apr 2007 19:12:30 -0400 B149.1-05 News Download the <a target="_blank" href="/hvac/files/Amendments.pdf"><b><font size="1">B149.1-05 Amendments</font></b></a> to the Natural gas and propane installation code, and the CSA-B149.1S1-07 Supplement No. 1 Package<br><br>There have been interesting amendments to Clauses 8.9.5 and 8.9.6, regarding plastic venting.<br>Download <a target="_blank" href="/hvac/files/ULCS636.pdf"><b><font size="1">Questions and Answers</font></b></a> regarding ULC S636 and plastic venting<br><Br>TSSA has also released two director's advisory's regarding plastic venting;<br><br>&nbsp;&nbsp;Director's <a target="_blank" href="/hvac/files/FS10107.pdf"><b><font size="1">Advisory FS-101-07</font></b></a> - Variance Conditions for Continued Use of Existing Uncertified Plastic Vent</b><br>&nbsp;&nbsp;Director's <a target="_blank" href="/hvac/files/FS10207.pdf"><b><font size="1">Advisory FS-102-07</font></b></a> - Variance Conditions for Vents Systems that were Installed Prior to August 1, 2007 but theAppliance Not Activated Until After August 1, 2007<br><br>&nbsp;&nbsp;An application for a <a target="_blank" href="/hvac/files/Variance.pdf"><b><font size="1">Variance/Deviation</font></b></a> form is required if Clauses 8.9.5 and 8.9.6 cannot be met. Director's Advisory FS-102-07 http://lethalclan.com/hvac/article.php?story=20070429192642480 http://lethalclan.com/hvac/article.php?story=20070429192642480 Mon, 16 Apr 2007 19:26:00 -0400 Director's Advisories <b>Variance Conditions for Vents Systems that were Installed Prior to August 1, 2007 but Appliance Not Activiated Until After August 1, 2007</b> <br><br><a target="_blank" href="/hvac/files/advisory/FS10207.pdf"><img width="125" height="160" src="http://lethalclan.com/hvac/images/articles/20070429192642480_1.jpg" alt=""><br><br><font size="1">Advisory FS10207</font></a><br><br><i>*Click image to enlarge.</i> <b>Clause (8.9.5)</b> - Venting systems, or total vent run if less than 3 ft (900mm), that employ plastic vents shall be installed such that the first 3 ft (900mm), from the appliance flue outlet is readily accessible for visual inspection except for direct vent appliances such as fireplaces that are intended to have short vent lengths to be concealed for decorative purposes.<br><br><b>Clause (8.9.6)</b> - <br>(a) Until July 1, 2008, vents constructed using plastic piping shall be certified to ULC S636 except for special fittings (non standard vent sizes and components) which may include:<br>&nbsp;&nbsp;a. entire vent systems supplied with the appliance that are not comprised of standard vent sizes and components;<br>&nbsp;&nbsp;b. transitions with or without condensing lines; and<br>&nbsp;&nbsp;c. termination kits.<br>(b) After July 1, 2008, vents constructed using plastic piping shall be certified to ULC S636.<br><br>Download and print the Application for a <a target="_blank" href="http://www.tssa.org/CorpLibrary/ArticleFile.asp?Instance=136&amp;ID=7925CAF2DCEA45A4B1756B5C7E7A1C69"><font size="1">Variance/Deviation FS09533</font></a>, to apply. Director's Advisory FS-101-07 http://lethalclan.com/hvac/article.php?story=2007042919045584 http://lethalclan.com/hvac/article.php?story=2007042919045584 Mon, 16 Apr 2007 19:04:55 -0400 Director's Advisories <b>Variance Conditions for Continued Use of Existing Uncertified Plastic Vent. </b> <br><br><a target="_blank" href="/hvac/files/advisory/FS10107.pdf"><img width="125" height="160" src="http://lethalclan.com/hvac/images/articles/2007042919045584_1.jpg" alt=""><br><br><font size="1">Advisory FS10107</font></a><br><br><i>*Click image to enlarge.</i> <b>Clause (8.9.5)</b> - Venting systems, or total vent run if less than 3 ft (900mm), that employ plastic vents shall be installed such that the first 3 ft (900mm), from the appliance flue outlet is readily accessible for visual inspection except for direct vent appliances such as fireplaces that are intended to have short vent lengths to be concealed for decorative purposes.<br><br><b>Clause (8.9.6)</b> - <br>(a) Until July 1, 2008, vents constructed using plastic piping shall be certified to ULC S636 except for special fittings (non standard vent sizes and components) which may include:<br>&nbsp;&nbsp;a. entire vent systems supplied with the appliance that are not comprised of standard vent sizes and components;<br>&nbsp;&nbsp;b. transitions with or without condensing lines; and<br>&nbsp;&nbsp;c. termination kits.<br>(b) After July 1, 2008, vents constructed using plastic piping shall be certified to ULC S636.<br><br>Download and print the Application for a <a target="_blank" href="http://www.tssa.org/CorpLibrary/ArticleFile.asp?Instance=136&amp;ID=7925CAF2DCEA45A4B1756B5C7E7A1C69"><font size="1">Variance/Deviation FS09533</font></a>, to apply. Director's Order FS-098-07 http://lethalclan.com/hvac/article.php?story=20070430032400807 http://lethalclan.com/hvac/article.php?story=20070430032400807 Mon, 16 Apr 2007 03:24:00 -0400 Director's Orders <b>Gaseous Fuels Code Adoption Document – Amendment.</b> <br><br><a target="_blank" href="/hvac/files/order/FS09807.pdf"><img width="125" height="160" src="http://lethalclan.com/hvac/images/articles/20070430032400807_1.jpg" alt=""><br><br><font size="1">Order FS09807</font></a><br><br><i>*Click image to enlarge.</i> NY Thermal - Trinity Boiler Safety Recall http://lethalclan.com/hvac/article.php?story=20070430054603631 http://lethalclan.com/hvac/article.php?story=20070430054603631 Wed, 11 Apr 2007 05:46:03 -0400 Product Recall <a target="_blank" href="http://www.nythermal.com/safety.htm"><img width="116" height="160" src="http://lethalclan.com/hvac/images/articles/20070430054603631_1.gif" alt=""><br><br><font size="1">Trinity Boiler Recall</font></a><br><br><i>*Click image to enlarge.</i> IMPORTANT SAFETY RECALL <br><Br>NY Thermal Inc. has determined that the condensate fitting located within the boiler may prematurely deteriorate. As NY Thermal Inc. cannot predict the occurrence of the anomaly, the condensate fittings must be replaced immediately. <br><br><b>Models Covered </b><br>All Trinity boilers manufactured between Nov. 28, 2005 and Jan. 8, 2007, or serial numbers greater than 06T-16000 must be upgraded. See diagram for location of information.<br><Br><img width="600" height="573" src="http://lethalclan.com/hvac/images/articles/20070430054603631_2.jpg" alt=""><br><br><b>What to Do</b><br>1. If your boiler was manufactured between Nov. 28, 2005 and Jan. 8, 2007, contact the person you purchased the unit from and advise that you require an immediate and mandatory safety update.<br>2. If you are unsure if your unit falls between the specified dates, contact NY Thermal Inc. and we will determine this for you. Please provide the serial number displayed on the silver decal on the outer casing of the boiler. (Example 06T-1234) <br><Br><b>Details</b><br><a target="_blank" href="/hvac/files/recalls/TrinityTi400.pdf">Trinity Ti 400 Safety Condensate Tee Upgrade</a><br><a target="_blank" href="/hvac/files/recalls/TrinityTi100-200.pdf">Trinity Ti 100-200 Safety Condensate Y Upgrade</a><br><Br>For More Information Contact NY Thermal Inc. at 1-800-688-2575. Laars Heating Systems - Gas Boilers and Water Heater Recall http://lethalclan.com/hvac/article.php?story=20070430160549384 http://lethalclan.com/hvac/article.php?story=20070430160549384 Tue, 03 Apr 2007 16:05:49 -0400 Product Recall <a target="_blank" href="http://www.csagroup.org/product_recalls/default.asp?articleID=9025&amp;language=english"><img width="116" height="160" src="http://lethalclan.com/hvac/images/articles/20070430160549384_1.jpg" alt=""><br><br><font size="1">Laars 9600 CB/HWG Recall</font></a><br><br><i>*Click image to enlarge.</i> CSA International and Laars Heating Systems Company announce a voluntary recall of gas boilers and water heaters - APB 13-07<br><br>In cooperation with CSA International, Laars Heating Systems Company of Rochester, New Hampshire announces the voluntary recall in Canada of approximately 82 units of the 9600 CB Series Condensing Boilers and 9600 HWG Series Condensing Water Heaters. Internal black plastic venting components in the boilers and water heaters can crack and leak flue gases, including carbon monoxide (CO), posing a risk of CO poisoning. <br><br>No injuries or incidents have been reported.<br><br>This recall involves the Laars 9600 CB Condensing Boilers and Laars 9600 HWG Condensing Water Heaters. The CB series is installed as a space-heating appliance to generate hot water used in a closed-system loop for hydronic heating systems, such as baseboards or radiant flooring. The HWG series is installed as a water heater to generate hot water for domestic use, such as showers, sinks and dishwashers. Consumers can identify the units by the label on the front that includes the headline “Mark II” at the top and then either “9600 CB” or “9600 HWG” directly under the headline. The jacket colours are either putty and black, or taupe (dark grey) and black. On the right side, a data plate repeats the information, and also contains the specific model number and BTU size as indicated below. Only the following product names and model numbers are included in this recall:<br><br>Models CB 250 and HWG 250 are manufactured with an internal CPVC vent pipe (grey in colour) and are not included in this recall. Any 9600 CB or 9600 HWG boiler or water heater with internal CPVC vent pipe (grey in clour) is not affected by this recall.<br><br>The affected models were sold nationwide from November 1998 through February 2007.<br><br>If the exhaust pipe is black and your product is included in this recall, consumers should contact the Laars Service Department to arrange for a free repair. In addition, consumers should visually inspect their appliance for any evidence of cracked or deformed internal vent material, including moisture inside the jacket or white residue inside or outside of the jacket. If there is any of this evidence, the unit should be shut down and the consumer should contact the Laars Service Department immediately. Call Laars Service Department at (905) 844-8233 extension 227 between 7 a.m. and 4 p.m. EST, Monday to Friday, to schedule a no-cost replacement of the affected part or visit www.Laars.com. The website will have an email link to contact the manufacturer. Have your model and serial numbers available.<br><br><img width="450" height="392" src="http://lethalclan.com/hvac/images/articles/20070430160549384_2.jpg" alt=""> <img width="209" height="466" src="http://lethalclan.com/hvac/images/articles/20070430160549384_3.jpg" alt=""> Ontario Power Authority Rebate http://lethalclan.com/hvac/article.php?story=20070430181629743 http://lethalclan.com/hvac/article.php?story=20070430181629743 Sun, 01 Apr 2007 18:16:29 -0400 Rebates <img width="182" height="79" src="http://lethalclan.com/hvac/images/articles/20070430181629743_1.jpg" alt=""><br><br><a target="_blank" href="http://www.powerauthority.on.ca/Page.asp?PageID=122&amp;ContentID=3968"> <font size="1">The Hot Savings</font></a> Rebate program ended March 31, 2007. Beginning April 1, <a target="_blank" href="http://www.powerauthority.on.ca/Page.asp?PageID=122&amp;ContentID=5464"><font size="1">The Cool Savings</font></a> Rebate program will encourage Ontario residents to reduce their electrical energy costs and help reduce the load on Ontario's electricity grid by providing rebates and coupons.<br><br>Visit <a target="_blank" href="http://www.coolsavingsrebate.com/"><font size="1">www.coolsavingsrebate.com</font></a> for more details about the rebate. <br><br><b>What is the Cool Savings Rebate Program?</b><br><br>The Cool Savings Rebate program encourages Ontario residents to install energy efficient heating and cooling systems, when replacing their existing systems by providing the following rebate offers;<br><br> &nbsp;&nbsp;* &#36;50 REBATE for the installation of a programmable thermostat. The programmable thermostat must be supplied and installed by a program registered contractor; <br> &nbsp;&nbsp;* &#36;50 REBATE for an air conditioner tune-up. Tune ups must be completed on existing Central Air Conditioning (CAC) system, in accordance with the program checklist by a program registered contractor;<br> &nbsp;&nbsp;* &#36;100 REBATE for the replacement of an existing furnace with an ENERGY STAR®- qualified/ECM-equipped mid – efficiency furnace or air handler; <br> &nbsp;&nbsp;* &#36;250 REBATE for the replacement of an existing furnace with an ENERGY STAR®- qualified/ECM-equipped high efficiency furnace or air handler; <br> &nbsp;&nbsp;* &#36;350 REBATE for the replacement of an existing Central Air Conditioning (CAC) system with an ENERGY STAR®- qualified system; <br> &nbsp;&nbsp;* &#36;750 REBATE for the replacement of an existing Central Air Conditioning (CAC)/furnace or air handler system with an ENERGY STAR® tier II CAC and ECM system. <br><Br>To be eligible for the rebates, services must be performed by a program-registered contractor. Full program details, including a ‘contractor-locator’ for finding a participating contractor near you, are available by visiting www.coolsavingsrebate.com or by calling 1-877- 797-9473.<br><br>If you are interested in becoming a participating program contractor, please e-mail hsrp@hrai.ca or call 1-800-267-2231 ext. 236 or ext. 248. Enbridge Residential Rebates http://lethalclan.com/hvac/article.php?story=20070430194548614 http://lethalclan.com/hvac/article.php?story=20070430194548614 Fri, 30 Mar 2007 19:45:48 -0400 Rebates Visit <a target="_blank" href="https://portal-plumprod.cgc.enbridge.com/portal/server.pt?space=CommunityPage&amp;control=SetCommunity&amp;cached=true&amp;CommunityID=285&amp;PageID=0">Enbridge Rebates &amp; Programs</a> webpage.<br><br><b>Programmable Thermostat &#36;15 rebate.</b> <br><br><a target="_blank" href="/hvac/files/rebates/egd15.pdf"><img width="150" height="78" src="http://lethalclan.com/hvac/images/articles/20070430194548614_1.gif" alt=""><br><br><font size="1">&#36;15 Rebate Coupon</font></a><br><br>Enbridge is pleased to offer a &#36;15.00 rebate on the purchase of a programmable thermostat. To receive the rebate, please complete the &#36;15 rebate coupon (PDF) and mail it, with a copy of the bill and the actual UPC symbol to:<br><br>Enbridge Gas Distribution<br>Attn: Rebate Processing Dept.<br>P.O. Box 650<br>Scarborough, ON M1K 5E3<br><br>&#36;15 will be credited to your account. Offer limited to one rebate per address. <br><br>* To be eligible for this rebate, all information must be completed, including a valid Enbridge Gas Distribution Inc. account number matched to the address indicated, a copy of the bill of sale for a programmable thermostat purchased and installed between April 1, 2007 and September 30, 2007, and the UPC code symbol. Only residential or commercial customers with natural gas heating systems rated under 300,000 BTU are eligible. Offer subject to cancellation without notice at any time. Forms must be received by Enbridge Gas Distribution Inc. on or before October 16, 2007. Please allow 6 to 8 weeks for the on-bill rebate credit. Offer valid in Enbridge Gas Distribution Inc. franchise area (Ontario only). Enbridge Gas Distribution Inc. is not responsible for lost mail. Rebate not valid without copy of the bill of sale.<br><br><br><br><b>Water Heater &#36;50 rebate.</b> <br><br><a target="_blank" href="/hvac/files/rebates/egd50.pdf"><img width="150" height="78" src="http://lethalclan.com/hvac/images/articles/20070430194548614_2.gif" alt=""><br><br><font size="1">&#36;50 Rebate Coupon</font></a><br><br>&#36;50.00 on the conversion from an electric, oil or propane water heater to a natural gas water heater. <br><br>Please mail completed rebate form and proof of purchase or copy of rental/lease agreement to the address on the form. Do not send form with your natural gas bill.<br><br>To receive the rebate, please complete the &#36;50 rebate coupon (PDF) and mail it, with a copy of the bill and the actual UPC symbol to:<br><br>Enbridge Gas Distribution<br>Attn: Rebate Processing Dept.<br>P.O. Box 650<br>Scarborough, ON M1K 5E3<br><br>&#36;50 will be credited to your account. Offer limited to one rebate per address.<br><br>* Receive a &#36;50 Rebate* on the purchase and installation or rental/lease when you convert your current non-natural gas water heater to a natural gas water heater. To be eligible for your rebate: Purchase or rent/lease, and install between April 1, 2007 and September 30, 2007 Fill in attached form Include copy of water heater proof of purchase or copy of rental/lease agreement Do not send form with gas bill payment Forms must be received by Enbridge Gas Distribution on or before October 16, 2007 *&#36;50 will be credited to your Enbridge Gas Distribution account. Offer limited to one rebate per address. <br><br><br><br><b>ENERGY STAR® high-efficiency natural gas heating system &#36;100 rebate.</b> <br><br><a target="_blank" href="/hvac/files/rebates/egd100.pdf"><img width="147" height="73" src="http://lethalclan.com/hvac/images/articles/20070430194548614_3.gif" alt=""><br><br><font size="1">&#36;100 Rebate Coupon</font></a><br><br>With increasing energy costs, now is the time to switch to a high efficiency heating system. Switching or upgrading your current heating system to a high efficiency natural gas heating source, will help you save money and make your home more energy efficient. Now, with the help of this rebate program, the switch to high efficiency has just become a little easier!<br><br>The ENERGY STAR mark is administered and promoted in Canada by Natural Resources Canada. Enbridge Gas Distribution promotes ENERGY STAR qualified natural gas furnaces that meet or exceed a 90% AFUE energy efficiency rating.<br><br>When you replace a heating system with an ENERGY STAR high-efficiency natural gas heating source, you are eligible for a &#36;100 mail–in rebate.<br><br>*&#36;100 will be credited to your Enbridge Gas Distribution account. Offer limited to one rebate per address.<br><br>To receive the rebate, please complete the &#36;100 rebate coupon (PDF) and mail it to:<br><br>Enbridge Gas Distribution<br>Attn: Rebate Processing Dept.<br>P.O. Box 650<br>Scarborough, ON M1K 5E3<br><br>* To be eligible for this rebate, all information must be completed, including a valid Enbridge Gas Distribution Inc. account number matched to the address indicated and a copy of proof of installation receipt for an ENERGY STAR qualified high-efficiency natural gas heating system purchased and installed between April 1, 2007 and September 30, 2007. Offer limited to one rebate per address. This offer may not be combined with any other Enbridge Gas Distribution Inc. natural gas heating system offers. Only residential or commercial customers installing a natural gas heating system rated under 300,000 BTU are eligible. New residential premises under construction are not eligible for rebate. Offer subject to cancellation without notice at any time. Forms must be received by Enbridge Gas Distribution Inc. on or before October 16, 2007. Please allow 6 to 8 weeks for the on-bill rebate credit. Valid in Enbridge Gas Distribution Inc. franchise area (Ontario only). Enbridge Gas Distribution Inc. is not responsible for lost mail. Rebate not valid without proof of purchase and installation receipt.<br><br>